Home
Tender
e-Catalogue
Article
Detail Material Information
Nama Produk
:
UHPLC
UOM
:
UNIT
Spesifikasi Produk
:
Spesification : Operating Principle : Serial dual-piston pump Flow Range : 0.001–10 mL/min, in 1 ?L/min increments Pressure Range : 2 – 70 MPa (20 – 700 bar, 290 – 10,100 psi). Compressibility Compensation : Fully automated, independent of mobile phase Flow Accuracy : ±0.1% Compressibility Compensation : Fully automated, independent of mobile phase Flow Accuracy : ±0.1% Flow Precision : <0.05% RSD or <0.01 min SD, whichever is greater Pulsation : Typically < 1.0% or < 0.2 MPa, whichever is greater Autosampler with Cooler 5 Type : Split Sampler CT Brand : Thermo Scientific Spesification : Operating Principle : Split loop injection Pressure Range : 2–70MPa, (20–700 bar, 290–10,100 psi) Injection Volume Range : Default: 0.01–100 ?L, min. step = 0.01 ?L Injection Volume Accuracy : Typically ±0.5% at 50 ?L and ±1% at 10 ?L water Injection Volume Precision : <0.25% area RSD for 3 ?L (caffeine in water) Typically <0.5% area RSD for 1 ?L (caffeine in water) Injection Linearity : r > 0.99999 (caffeine in water) Injection Cycle Time : Down to 8 s depending on separation conditions Minimum Sample Required : 2 ?L at 1 ?L injection volume Carry Over (UV) : <0.002% with caffeine (typically: <0.0004%) Needle Wash (external) : 1 solvent, dip rinse and continuous rinse Thermostatted Column Compartment with CoolerOperating Principle : Still air and forced air Temperature Range : 5–85 ? C in 0.1 ? C increments (max 18 ? C below ambient) Temperature Stability : ±0.05 K Temperature Accuracy : ±0.5 K (up to 80 °C) Heating Performance : <15 min, 20–50 °C, ±1 K Cooling Performance : <15 min, 50–20 °C, ±1 K Capacity : 2 column slots UV-VIS Detector pesification : Optical Design : UV/VIS/NIR photometer (tunable Czerny-Turner monochromator) with additional internal reference beam Light Source : Deuterium lamp Tungsten lamp (optional) Wavelength Range : 190–750 nm (with deuterium and tungsten lamp) Spectral Bandwidth : 6 nm at 254 nm Wavelength Accuracy : ±1 nm Wavelength Repeatability : ±0.1 nm Number of Signal Channels : Up to two Data collection rate (single- channel) : Up to 125 Hz oftware CM LICENSE CODE: NEW 5 ENTERPRISE CLIENT 5 THERMO INSTRUMENT FOR ENTERPRISE 5 f Local Suppy PC 5 Monitor 5 DELL LED Monitor 22 " Printer 5 Printer HP Laserjet M107W WiFi Receiver 5 UPS 3 KVA Build in isotrans
Harga
:
379,047,620
Ajukan Penawaran
Chat With
Offline
Jam Operasional 08:00:00 s/d 17:00:00